1. Vertical
placement of chimney's components is preferable during transportation,
suspending assembling and storage. Knocking and scrape are
prohibited.
2. Wearing anti-slip rubber gloves is preferable during
suspending assembling for safe reason.
3. No distortion and oil spot in flange face of inner tank
before chimney-assembling first. After that, spreading sealing
glue in flange face, and then combining the two slices of
flange together face to face.
4. Clip closely outer circle of flange with V-shape hoop
and then screw down the bolts.
5. After spreading sealing glue in flute of outer tank,
connecting two sections of outer tanks together with outer
circle hoop and then screwing down the bolts.
Attention: Spaces of connection between two sections